<LOGO>
FM Transmitter Measurement Report
Created: 2024-03-21 11-49-01
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.90 MHz 5/5, 42 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
8 kHz 43 kHz 18630 0,1127
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-0,9 dBr -0,55 dBr -0,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 11:48, 21.03.2024
RT
"Interview Plus - Zora Hesova, arabistka z Filozofickeho ustav..."
AF EON
91.3, 91.5, 92.6, 92.8, 93.3, 93.5, 93.9, 94.1, 95.4, 97.8, 100.8, 101.5, 101.9, 103.6, 107.2 MHz -
FM Scope Max at: 43 kHz MIN: 8 kHz % above 77 kHz: 0,1127 Acquired: 2024/03/21 11:48:59 Total samples: 18630 Equivalent time: 0:15:31 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: -0,1 dBr MIN: -0,9 dBr AVE: -0,55 dBr % above 0,2 dBr: 0,0 Last value: -0,6 dBr (2024/03/21 11:48:58) 11:36 11:38 11:40 11:42 11:44 11:46 11:48 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality